Water Hardness Test Kits: How to Choose

Choose a test that gives you the level of detail you need, in units you can use.

Source review: September 15, 2026. This is a comparison of manufacturer information. We have not independently lab-tested these kits.

Hach

5-B Total Hardness Test Kit

Checking untreated water or softener performance with a numerical reading

Useful for: Drop-count titration; Reports total hardness in grains per gallon.

Limitations: Requires careful counting; Check the measuring range and reagent expiry.

View product and current price

API

General & Carbonate Hardness Test Kit

Users who want both hardness and alkalinity measurements and can convert units

Useful for: Separate GH and KH tests; Manufacturer provides a conversion chart.

Limitations: GH is reported in German degrees; KH is alkalinity, not a substitute for total hardness.

View product and current price

Titration or test strips?

MethodUseful forLimitation
Drop-count titrationA numerical hardness reading for settings or before/after checksSample volume, drop size and endpoint judgement affect the result
Colour stripsA quick hardness bandColour bands usually do not resolve a precise softener setting
Multi-parameter kitScreening several water characteristicsCheck the included hardness range; a hardness result does not establish drinking-water safety

Check what the kit actually measures

Total hardness measures calcium and magnesium expressed as calcium carbonate. A TDS meter measures conductivity and estimates dissolved solids; it does not directly measure total hardness. In an aquarium kit, GH is general hardness, while KH is an alkalinity measurement.

Hach's 5-B is a total-hardness kit. It does not separately report calcium hardness. Check the kit's current instructions for its measuring range, sample size and conversion.

Convert your result correctly

  • GPG × 17.1 = ppm (mg/L) as calcium carbonate.
  • ppm ÷ 17.1 = GPG.
  • For API's German-degree scale: °dGH × 17.9 = ppm, then divide by 17.1 for GPG.

For example, 10 °dGH is 179 ppm, or about 10.47 GPG. The German-degree-to-GPG multiplier is approximately 1.047.

API manufacturer instructions and conversion chart · GPG–PPM converter

Get a representative sample

Follow the instructions for your particular kit, including sample volume, mixing and reading time. For sizing a softener, test untreated cold water upstream of the unit. For a performance check, compare untreated and treated samples. Do not assume that leaving water in the pipes overnight improves a hardness measurement.

Repeat an unexpected result with fresh reagents and a clean container. Recheck after a change in source water or softener performance. Use a suitably accredited laboratory when you need certified results.

Already have a reading?

Use the measured hardness and your household water use to estimate a softener's required capacity.

Calculate softener requirements